Well      04.03.2020

Doublet water deferrization system. Water deironing stations ecomaster doublet. Source water requirements

Deironing installations "Duplet" - filters for removal of iron and hydrogen sulfide. The use of a highly efficient water aeration system and a non-reagent filter-iron remover makes it possible to purify water from iron and remove up to 10 mg/l of iron, up to 0.5 mg/l of manganese and up to 2 mg/l of hydrogen sulfide and sulfides.

Iron removal filters of the "Duplet" series consist of a washing strainer, an aeration system (including a compressor with a control system) and a chemical-free iron-removing filter.

Water deironing plants, or in short - the water deironing filter of the Doublet-N series (pressure) are used with sufficient supply and pressure of the source water and consist of: a mud washing filter, an aeration column, an oil-free compressor with a control system, an air separating valve, a reagent-free filter - deironing agent, a single thermal protection casing, flow sensor and pressure gauge.

Water deironing plants of the Doublet-RS series (with a jet break) are used at low source water pressure and insufficient water supply and include: a mud filter, an oxidizing tank, an oil-free compressor with a control system, a pumping station (including booster pump, membrane tank and pressure switch), a reagent-free iron remover in a thermal protective casing (ironing filter) and an automation system. Using an oxidation tank and pumping station provide the required water supply, pressure and water supply for iron removal.

To improve the organoleptic properties of water, filters for removing iron "Duplet" can be equipped with a sorption cartridge filter.

Water Requirements
Iron total - no more than 5 mg / l., incl. iron (II) - no more than 70%.
Manganese - no more than 0.2 mg/l.
Hydrogen sulfide and sulfides - up to 0.1 mg/l

In the words of a specialist:
“Water iron removal is one of the most difficult tasks in water treatment. Only a detailed analysis of various situations will allow you to choose a method of iron removal that will be optimal in each individual case. It should be remembered that deferrization of water various methods allows applicability within certain limits and has both advantages and disadvantages in various situations. We at Ecodar strive to offer a wide range of solutions that allow iron removal in water various conditions and with different indicators of water "

Brief product description: Ecomaster DUPLET aeration and iron removal station is a modern filter for water purification from iron and hydrogen sulfide.

Detailed product description: High content iron is one of the characteristic and complex problems, characteristic of both the Moscow region and almost all other regions of Russia.

The presence of iron in drinking water impairs its taste and odor, makes it Brown color. An excess of iron adversely affects both internal organs human, and on his skin, causing allergic reactions.

In addition to harm to health, iron leads to the appearance of yellow smudges on plumbing, clogging and corrosion of pipelines, and failure of expensive equipment.

"Full construction"

The station is delivered ready for connection. No additional accessories and Supplies purchase is not required.

Qualitatively

Unlike plants with multifunctional loading, which solve a number of problems, but do not remove dissolved gases, the Ecomaster DUPLET system not only purifies water from high iron content, but also removes turbidity and unpleasant odors.

The station uses only modern components manufactured in the USA by Clack Corporation (housings, Russified control valves) and Air Pump (compressor).

Effective

The DUPLET water deironing station uses a highly efficient aeration system and a non-reagent filter - deironing agent, which allows removing up to 10 mg/l of iron and up to 2 mg/l of sulfides and hydrogen sulfide.

The model range of this equipment allows you to purify water in both small country houses, and in large cottages. DUPLET systems equipped with an oxidizing tank provide an additional supply of water.

The Ecomaster DUPLET is compact and can be installed in confined spaces.

The Ecomaster DUPLET is equipped with thermal protection covers to prevent condensation.

Safely

The water deironing station does not use hazardous chemicals. Discharge of filtered contaminants is not dangerous for local treatment facilities(septic tanks).

Iron removal filters DUPLET are equipped free of charge with the Aquastop anti-leakage system.

Easy to serve

The water deironing system does not require consumables.

Control elements are Russified and easy to set up.

Unlike inefficient cartridge water iron removal plants, the station does not require constant replacement of any parts or loading.

The presence of iron in drinking water impairs its taste and odor, giving it a brown color. An excess amount of metal adversely affects both the internal organs of a person and his skin, causing allergic reactions.

In addition to harm to health, iron leads to the appearance of yellow smudges on plumbing, clogging and corrosion of pipelines, and failure of expensive equipment.

Installation of aeration and deferrization of waterEcomasterDOUBLET


Turnkey water deironing plant »

Water deironing stations in Moscow and St. Petersburg supplied ready for connection. No additional accessories and consumables for iron removal are required to be purchased.

The cost of the Ecomaster DUPLET iron removal system for a private house includes:

    equipment for removing iron from water (iron removal filter);

    filters for water purification from odor and hydrogen sulfide;

    guarantee for equipment, work and clean water;

    chemical analysis of water after installation of the system;

    delivery within MO; Leningrad region

    installation and commissioning;

    free one-time service within 3 months after launch (within Moscow region) Leningrad region).

Qualitatively

Unlike water deironing plants with multifunctional loading, which solve a number of problems, but do not remove dissolved gases, water deironing stations for a private house Ecomaster DUPLET It is designed not only to purify water from iron, but also to remove turbidity and unpleasant odors.

Water purification systems from iron are equipped only with modern components manufactured in the USA by Clack Corporation (housings, Russified automation) and Air Pump (compressor).

Effective

The stations for a private house DUPLET use a highly efficient system of aeration and a reagent-free iron-removal filter, which allows removing up to 10 mg/l of iron and up to 2 mg/l of sulfides and hydrogen sulfide.

The model range allows you to purify water both in small country private houses and in large cottages. DUPLET systems equipped with an oxidizing tank provide an additional supply of water.

Comfortable

The Ecomaster DUPLET deironing filter is compact and can be mounted in a limited space.

The water deferrization plant in a private house DUPLET is equipped with thermal protective covers that prevent the formation of condensate.

Safely

The station does not use hazardous chemicals. Discharge of filtered pollutants is not dangerous for local treatment facilities (septic tanks).

Easy to serve

Water purification systems from iron do not require consumables.

The control elements of the installation are Russified and easy to set up.

Unlike inefficient cartridge deironing units, the Ecomaster DUPLET deironing filter for a private house does not require constant replacement of any parts or loading.


aeration stationEcomasterDOUBLET- This modern system to remove iron and hydrogen sulfide from water.


Model Doublet- 1.5N Doublet- 2.5N Doublet- 3.5N
Productivity, m 3 / hour up to 1.5 up to 2.5 up to 3.5
Operating temperature range, o C 2-37
Operating pressure range, bar 2,5-6,0
Regeneration duration, min 20 34 34
The volume of water for regeneration, l 500 1160 2200
Product dimensions, mm 650 X 280 X 1650 750 X 320 X 1600 950 X 420 X 1940
Connecting dimensions (inlet/outlet), mm 25/25 25/25 32/32
Supply voltage, V 220
Power consumption, W:
- Compressor
- Filter-iron remover
195/205
190
5/15

Basic water requirements

Iron total:

    no more than 5 mg/l for DUPLET-N

    not more than 10 mg/l for DUPLET-RS

Hydrogen index - 6.2-8.5

Suspended solids - no more than 5 mg/l

Oil products - no

Hydrogen sulfide and sulfides - up to 0.2 mg/l


Key mechanisms of control automation and other parts of the equipment are subject to fouling. This affects the performance of the entire System and eventually leads to a deterioration in the quality of treated water. Any water treatment and iron removal system for a private house is a complex engineering device, and its elements require high-quality and regular maintenance.

Stations Ecomaster DUPLET-N (pressure) are used with sufficient supply and pressure of source water and consist of mechanical cleaning, an aeration column, an oil-free (air) compressor with a flow sensor, a control system, an air-separating valve, a chemical-free iron remover in a thermal protective casing (iron removal filter for a private house), a single thermal protective casing and a pressure gauge .

DUPLET-RS systems (with jet break) are applied at low pressure and insufficient water supply and include mechanical cleaning, oxidizing tank, oil-free (air) compressor, pumping station (including booster pump, membrane tank and pressure switch), reagent-free iron remover in a thermal protective casing and automation system. The use of an oxidizing tank and a pumping station provide the required water supply, pressure and supply for iron removal.

To improve the organoleptic properties, Ecomaster DUPLET water treatment plants can be equipped with an additional sorption (carbon) cartridge.

Russified interface automatic device management
Protection of filter housings against condensation
UpFlow and DOW® Amberlite for softeners
Equipment warranty - 4 years
Free delivery within the Moscow region Free delivery within the Leningrad region
Strapping kit
Installation and commissioning
Chemical analysis of water after installation of the system
Free one-time service within 3 months after launch (within the Moscow region, on weekdays)
Free one-time service within 3 months after launch (within the Leningrad region, on weekdays)
Free control water analysis within 2 months after launch
Legal guarantee for clean water

Comparison of service packages included in the price of Ecomaster equipment
Write a review Ask a Question

Water deironing systems of the Doublet series - systems for removing iron, turbidity, manganese *, as well as
hydrogen sulfide and sulfides. Using a highly efficient water aeration system and reagentless
iron removal filters allow removing up to 5 mg/l of iron, up to 0.2 mg/l of manganese and up to 0.1 mg/l
hydrogen sulfide and sulfides.
Doublet series systems consist of a flushing strainer, an aeration system (including a compressor with
control system) and a non-reagent iron-removing filter.
Water deironing systems of the Duplet-N series are used with sufficient supply and initial pressure.
water and consist of: mud washing filter, aeration column, oil-free compressor with the system
water flow control, air-separating valve, reagent-free iron-removing filter,
a single thermal protection casing, flow sensor and pressure gauge.
Water deironing systems of the Duplet-RS series are used at low pressure of source water and
insufficient water supply and include: flushing mud filter, oxidation tank, air
compressor with control system, pumping station (including booster pump, diaphragm tank and relay
pressure), a reagent-free filter-iron remover in a thermal protective casing and an automation system.

The use of an oxidizing tank and a pumping station provide a supply of water, the required pressure and water supply.
To improve the organoleptic properties of water, these systems can be equipped with a sorption cartridge filter.

Name Equipment Description Height, m ​​/ Installation area, m2
1,5 (m 3 / h)* 2,5 (m 3 / h)* 3,5 (m 3 / h)*
Pressure
Doublet-N 1,65 / 0,2 1,65 / 0,3 1,95 / 0,5
Doublet-N with
adsorption block
Iron and hydrogen sulfide removal system 1,65 / 0,3 1,65 / 0,4 1,95 / 0,5
With jet break
Doublet-RS Iron and hydrogen sulfide removal system 1,95 / 0,7..0,8 1,95 / 1,2..1,5 1,95 / 1,8..2,0
Doublet-RS with
adsorption block
Iron and hydrogen sulfide removal system 1,95 / 0,7..0,8 1,95 / 1,2..1,5 1,95 / 1,8..2,0

* Maximum productivity (m 3 /h).

Source water requirements

    • Hydrogen index - 6.8-8.5
    • Water temperature - plus 2-37 0 С
    • Oil products - absence.
    • Iron total - no more than 5 mg / l., incl.
      iron (II) - no more than 70%.
    • Manganese - no more than 0.2 mg/l.
    • Hydrogen sulfide and sulfides - up to 0.1 mg / l.
    • Oxidability permanganate -< 5,0
      mgO 2 /l
    • Solid abrasive particles - no.
  • terms of Use

    Water pressure at the station
    for the "H" series - from 2.5 to 6.0 atm.
    for the "RS" series - from 0.5 to 6.0 atm.

  • The maximum consumption of water, arrive-
    for installation - not less than required
    water supply for backwashing
    (see table)

  • Humidity in the room -< 75%
    Mains voltage - 220 V ± 5%,
    50 Hz.

The doublet series deironing filter is a proven water purification scheme for removing the smell of hydrogen sulfide, all kinds of volatile impurities, including toxic and sharp bad smell, as well as for the oxidation of dissolved iron. The undeniable advantage of a pressure iron remover is high performance with relatively small overall dimensions.

Principle of operation: water enters the aeration column, where the odor of hydrogen sulfide and other impurities is stripped off and oxidized. After aeration and oxidation of dissolved iron compounds and their precipitation, water under pressure enters the charging filter-iron remover, where the iron is additionally oxidized and retained in the thickness of the filtering agent.

TECHNICAL SPECIFICATIONS

  1. Compressor power supply - 220V/50Hz.
  2. Working pressure 2.5-6 atm.
  3. System performance from 0.5-4.5 m3/h.
  4. Working temperature from 5 to 36°С.
  5. Power consumption of the compressor 150-230 W.
  6. The power consumption of the control valve is 3 W.