Mixer      03/04/2020

Critical moments in the construction of houses made of aerated blocks. Our analogue of a house made of aerated concrete. Useful videos. What can aerated concrete do? Foam concrete panels

All products made from cellular concrete must be manufactured using the same technology and in the same type of interchangeable forms, using a cutting system in which a raw aerated concrete mass of 5-15 m3 in volume is cut into products of the required sizes.

The following products are made from autoclaved aerated concrete:

Small wall blocks;
- unreinforced large wall blocks;
- reinforced large wall blocks;
- integrally molded wall panels;
- composite wall panels;
- volumetric blocks;
- partition slabs;
- interfloor floor slabs;
- coating slabs;
- heat-insulating boards;
- jumpers;
- acoustic plates;
- decorative plates.

2.1. Small wall blocks

Unreinforced small blocks of aerated concrete are manufactured and accepted in accordance with GOST 31360. They have classes of compressive strength not lower than B1.5 and density grades not higher than D700.

Blocks are made I and II categories.

Size deviation

BlocksIcategories:

Length ±3 mm;
- width ±2 mm;
- height ±1 mm.

BlocksIIcategories:

Length±4 mm;
- width±3 mm;
- height ±4 mm.

Walls made from small blocks are laid using mortars or glue. Aerated concrete blocks can be used to make external load-bearing, self-supporting and curtain walls, as well as internal load-bearing walls and partitions.

For normal operating conditions, blocks must have a frost resistance of at least F 25, for wet conditions - not lower F 35. In areas of the Far North with estimated temperatures below - 40 o C, frost resistance grades should be no lower, respectively F 35 and F 50.

2.2 Large wall blocks

Non-reinforced (according to GOST 31360) include products with maximum dimensions of length up to 1500 mm, width up to 1000 mm, thickness up to 600 mm. They are intended for direct installation of large-block and large-panel buildings or for enlarged assembly in panels.

Large blocks are used for the construction of external and internal walls of all types: curtain walls, self-supporting and load-bearing. External wall blocks are recommended to be finished surface layer at the factory and delivered to the construction site in finished form.

The frost resistance grade must be no lower than F 25, in wet conditions - F F 35 and F 50.

At blocks I and II categories, the same size deviations are allowed as for small blocks.

2.3 Reinforced large blocks and wall panels

Reinforced large blocks and wall panels are manufactured according to GOST 11118.

A large reinforced block is an element with an area of ​​less than 1.8 m2, reinforced with structural and working reinforcement, designed to withstand technological, transport, installation and operational loads. The wall panel can be solid or composite.

A solid external wall panel is a factory-made product with an area of ​​at least 1.8 m2.

A composite wall panel is a panel assembled from initial elements (including large blocks with glue, mortar, by welding steel embedded products or using ties.

The initial element is a reinforced large block, combined into a mounting panel.

Composite panels are more preferable, since only they allow the use of cutting technology, are more crack-resistant, require less reinforcement consumption, and make better use of molds and an autoclave.

To increase crack resistance, prestressed reinforcement can be provided, as well as tension ties used for enlarged assembly and installation.

The density grade of aerated concrete used ranges from D400 to D800, the compressive strength class is from B1.5 to B7.5.

Panels can be hinged, self-supporting or load-bearing. For external longitudinal walls, curtain wall panels should be used, allowing the use of the lightest and most efficient aerated concrete of the D400 brand. Single-row external walls are supplied fully finished with joinery and glazing inserted. The exterior department should provide an expressive architectural appearance of the facade and its durability.

The frost resistance grade must be no lower for normal operating conditions F 25, in wet conditions - F 35. For conditions of the Far North, respectively F 35 and F 50.

Installation of panels can be carried out with mortar, adhesives (mastics) and dry with the help of elastic gaskets. Self-gripping traverses should be provided as mounting devices. Composite panels are lifted by tie rods, which can be removed after installation. It is recommended to make the joined edges of the panels flat, without ridges and grooves. Blowing and wetting are prevented by sealing with mortar, poroizol and elastic mastics. Anchor connections between panels and adjacent structures should be made without molded embedded parts, and the workability of cellular concrete should be used.

Channels and grooves for hidden wiring And engineering communications It is recommended to perform it in the factory with electrified cutters and drills. Calculation wall panels strength and deformation should be carried out in accordance with STO 501-52-01-2007.

Transportation of panels should be carried out by panel carriers in a state secured from dynamic influences using elastic gaskets. It is recommended to use mounting from wheels. During transportation and storage, panels must be protected from moisture and mechanical damage. Other technical requirements are set out in STO 501-52-01-2007.

2.4 Volume blocks

Volumetric blocks (block rooms) made of aerated concrete are a new progressive type of structure. They are assembled using glue and strands from individual flat elements obtained using cutting technology. The blocks are made room-sized and look like a box closed on all sides. They can be suspended (hung on a frame) or load-bearing. In the first case, the thickness of the internal walls must be at least 8 cm. For load-bearing blocks, the thickness of the internal walls is assumed to be at least 10 cm and the compressive strength class is at least B3.5.

Floor elements in both options must have the same minimum thickness and class. The size of the air gap in the walls and ceilings must be at least 5 cm. It is recommended to make external walls a curtain structure; they transfer their weight to the ceilings and transverse load-bearing walls.

Installation of the blocks is provided dry in order to ensure the possibility of winter construction at any temperature. Volumetric blocks are supplied fully finished for installation. Finishing is carried out either at an cellular concrete plant, if it is connected to the construction site by a good road, or at an on-site closed site, where the aggregate assembly of blocks is carried out.

Loading of volumetric blocks is carried out using a balancing beam, ensuring the absence of distortions. The blocks are transported by trailers with a soft platform suspension.

During installation, the blocks are protected from moisture.

2.5 Panels for partitions

Partition panels made of aerated concrete are manufactured in accordance with GOST 19750.

Panels of partitions (non-load-bearing) made of aerated concrete can be multi-row cut or single-row cut.

Reinforced slabs (panels) of partitions are made from aerated concrete grades D400-D800, classes B1.5-B7.5, height per floor, thickness from 8 to 30 cm, width from 60 cm. Reinforced with a central mesh of cold-drawn wire for thicknesses from 80 mm to 120 mm or two meshes for thicknesses from 160 to 300 mm. Frost resistance - no less F 15. In wet rooms, slabs are protected with a painted hydrophobic vapor barrier.

The panels are joined using glues and mastics. They are attached to adjacent cellular concrete structures using nails. Drive pins, dowels, staples and screws. They must be lifted using pincer grips (without hinges).

Delivery and storage are carried out on pallets in bags protected from moisture.

Technical requirements are set out in GOST 19570 and STO 501-52-01-2007.

2.6 Floor panels

Floor panels are manufactured in accordance with GOST 19570 from aerated concrete of classes from B2 to B10 and density grades from D500 to D1200. Their width can be from 600 to 1800 mm. Length 2400-6000 mm, thickness 140-250 mm. With a thickness of 220 mm, they become interchangeable with hollow-core panels made of heavy concrete and can be used in standard brick houses, as well as during their reconstruction. Frost resistance - no less F 25.

Reinforcement can be carried out using prestressed reinforcement (wire or rod), prestressed on cellular concrete or reinforced concrete bars (bar reinforcement).

Embedded mounting loops can be provided if pincer grips and traverses are not used.

During calibration, panels can be used for “dry” installation, i.e. without installing support mortar beds (if the support also occurs on calibrated surfaces). Longitudinal and transverse seams between panels are reinforced and filled cement mortar, and reinforcement cages are laid above the supports in the longitudinal seam.

Slots, channels and holes for electrical wiring and utilities can be cut on the construction site using electric cutters, drills, disk or chain saws, as well as hand plows. It is prohibited to hammer concrete with impact tools. Grooves and other weakening should not reduce the load-bearing capacity and rigidity of products below the required values.

The calculation of floor decking is carried out for strength, rigidity and crack opening in accordance with the design standards for structures made of cellular concrete and STO 501-52-01-2007. The maximum design load for a length of 6 m should not exceed 600 kg/m2 (6 kPa) (over dead weight).

Storage and transportation are carried out in the working position (flat) on pads, protected from moisture.

Technical requirements are set out in GOST 19570 and STO 501-52-01-2007.

2.7 Cover panels

Aerated concrete roofing panels are made from concrete of classes from B2 to B3.5, grades D400-D600. Their length is from 2.4 to 6 m, width - from 0.6 to 1.8 m, thickness - from 250 to 400 mm.

To increase the thermal insulation ability of coatings, it is recommended to make them ventilated. Ventilation becomes necessary in panels laid over wet areas, even if there is a lower vapor barrier.

The frost resistance of the material of ventilated panels must be at least F25, for non-ventilated panels - at least F35, respectively, for the conditions of the Far North - F35 and F50.

Load-bearing coating panels are reinforced based on operational loads (possibly with prestressed reinforcement).

Non-load-bearing panels (laid on a reinforced concrete base) are reinforced to accommodate demoulding and transport loads. The upper plane of the panels (including above the channels that do not extend to the surface) is reinforced with an anti-shrink mesh made of cold-drawn wire with a diameter of 3-4 mm with a cell side of 10-15 cm. Ventilation ducts(grooves) in coating slabs manufactured using cutting technology must extend to the surface and be arranged by milling.

The minimum cross-sectional area of ​​the channel is 15 cm 2, the maximum step is 20 cm and increases in proportion to the cross-sectional area of ​​the channels. Mounting loops are not provided in case of using pincer grips and traverses.

It is recommended to cover panels with a smooth top surface at the factory with a layer of bitumen or paste them with roofing felt in order to simplify roofing works and reducing moisture during transportation, storage and installation.

In case of calibration of load-bearing panels and supporting surfaces, dry installation is allowed. Anchoring is done using associated supporting structures strip anchors nailed to the covering panels. When installing the covering panels, the longitudinal and transverse seams that serve to pass through the channels are monolithic only to the level of the bottom of the channels. Above the supports, reinforcement cages are inserted into the solution of longitudinal seams.

Coating slabs are calculated for strength, rigidity and crack opening in accordance with STO 501-52-01-2007.

Transportation and storage are carried out in the working position, on pads, taking measures to prevent moisture. At the same time, the natural drying of the panels before installation should not be impaired.

2.8 Thermal insulation boards

Thermal insulation slabs are manufactured in accordance with GOST 5742, with dimensions of 100 * 50 * 8-24 cm (graded by 2 cm) from cellular concrete of density grades D350 and D400 and compressive strength classes B0.5 and B0.75, respectively.

For civil engineering, taking into account unification, the introduction of cutting technology and the achieved quality of cellular concrete, recommended dimensions are 600 and 1200 mm in length, 200 and 300 mm in height and 50, 80, 100 and 160 mm in thickness. The compressive strength class for bulk grades D350 and D400 must be at least B1 and B1.5, respectively.

Release humidity of thermal insulation slabs that have the ability to dry out during operation (attic floors, ventilated roofs, external cladding walls, as well as basement ceilings), should be no more than 25% (by weight). The release humidity of the sealed thermal insulation should not exceed 12%.

Frost resistance should not be lower than 15 (for the Far North - F 25).

Thermal insulation boards must be manufactured using cutting technology, followed by calibration and mounted with glue.

Thermal insulation slabs can serve as a formwork shield (permanent formwork) when concreting monolithic walls, subsequently performing decorative and insulating functions.

Additional insulation slabs are sawed off from the main slabs with a hacksaw, circular saw or chain saw.

Thermal insulation boards are supplied on pallets in bags protected from moisture, but allowing natural drying.

2.9 Jumpers

Aerated concrete lintels are used to cover window and doorways in outdoor and interior walls from cellular concrete. In external walls, lintels are used only in case of block masonry.

The lintels are made of aerated concrete of density grades from D500 to D700, compressive strength classes B2-B5. The thickness of the lintels is 200-250 mm. The length can vary from 1200 to 3600 (graded in 0.3), height - from 200 to 400 mm.

The lintels can be non-load-bearing, in which case they are reinforced structurally, or load-bearing with design working reinforcement in the tension zone. The lintels must have a tempering humidity and frost resistance corresponding to the adjacent wall elements.

The installation of jumpers must be done using pliers (without mounting loops) or manually (for jumpers weighing up to 60 kg).

Support occurs on mortar or adhesive (for calibrated products) beds or reinforced concrete belts. The support depth of the lintels must be at least 150 mm.

The lintels are calculated for strength along vertical and inclined sections in accordance with the design standards for structures made of cellular concrete or STO 501-52-01-2007.

They are transported and stored in the working position in bags protected from getting wet.

2.10 Acoustic slabs

Autoclaved aerated concrete has good sound-absorbing ability and can be used as acoustic cladding for indoor spaces in public buildings, restaurants, shops, and playrooms.

Density brand of acoustic slabs D400, strength class not less than B1.5, dimensions 400x400, 450x450, 450x600 mm, with a thickness of 50 mm. Tolerance for length, height and thickness up to 2 mm. Humidity and frost resistance are not standardized. The average sound absorption coefficient in the range often 100-3200 Hz should be at least 0.5. To increase the acoustic properties in slabs 50 mm thick, grooves with a cross-section of 20x20 mm (with an axial step of 40 mm) can be cut, filled with mipore (foam rubber).

The slabs are fastened to the ceiling with staples or screws, and to the walls with glue or mastic. Delivery is made in packages in cardboard containers of 1-1.5 m 3 in one package.

Due to the workability, durability and cost-effectiveness of aerated concrete, decorative slabs with relief and pigment applied to them can be made from it for decorating the interiors of public buildings.

Brand by density decorative slabs D500-D700, strength class B1.5-B2.5, length 600 mm, height 200 mm, thickness 50-80 mm. Tolerance for length and height is up to 2 mm, for thickness up to 1 mm. Holiday humidity and frost resistance are not standardized.

Fastening to the walls is done using adhesives and mastics. Delivery is carried out in packages on pallets.

Aerated concrete is an artificial stone that has recently been used in the construction world. It has great thermal conductivity and strength, is lightweight and easy to install, and has found its application in the construction of partition and wall blocks. Due to the precise parameters of aerated concrete floors, an even and smooth coating is ensured, which does not require subsequent finishing. Aerated concrete walls are prefabricated prefabricated slabs. Great demand for such products has arisen due to their environmentally friendly components that do not affect human health.

Where are they used?

Aerated concrete slabs are used in the installation of floors between floors of buildings, and are also used for the construction of walls. Aerated concrete structures are used in the construction of houses whose height does not exceed three floors. Used for floors aerated concrete blocks With technical characteristics, suitable for the weight of the vaults.

Advantages

  • Aerated concrete blocks have no errors in size. Thanks to this, the surface is smooth, which significantly reduces the cost of finishing buildings. But there is one condition - the walls must also be free of reliefs, cracks and potholes. To get rid of defects, putty and sanding are used.
  • When installing an aerated concrete slab, you do not have to spend a lot of time or make a lot of effort.
  • On to the pros of this material include the lightness of the blocks, which during operation do not exert a load on the load-bearing walls of buildings.
  • When installing aerated concrete elements, a small amount of auxiliary equipment is used.
  • When using aerated concrete in the construction of houses with a small number of floors, the following characteristics of the material are taken into account: strength, fire resistance, sound insulation, thermal insulation and moisture resistance. The material is odorless, with environmentally friendly components.
  • An advantage when working with aerated concrete floors is their convenience when installing balcony bases.

Flaws


Main types

Building blocks made of foam concrete are autoclaved and non-autoclaved. The second type is the best in price and quality characteristics. When using autoclave plates, you need to be prepared that after installation, during operation, they “grow old.” In the production of autoclaved cellular aerated concrete slabs, lime is used, which causes the materials to harden as a result of pressure and temperature. In the preparation, cement is used as a binding element, as a result of which the particles harden naturally.

Floor slabs for aerated concrete come in the following types:

  • monolithic;
  • aerated concrete;
  • wooden beams;
  • reinforced concrete slabs;
  • metal beams.
When using aerated concrete slabs, it is necessary to install a reinforced ring belt.

A reinforced or aerated concrete floor is a monolithic structure consisting of grooves into which slabs are inserted. When working with aerated concrete slabs, they are laid on a reinforcing layer. In this case, the reinforcing structure is treated with anti-corrosion coatings.

The sizes of the slabs are different, but the main condition is that they must protrude 20 cm beyond the span. Prefabricated ones are also used, the production of which takes place in factories; They are more economical than monolithic ones. Aerated concrete structures are distinguished by their light weight, which cannot be said about reinforced concrete ones.

Monolithic floors about 3 centimeters thick include reinforcing mesh, filled with concrete. Such aerated concrete house designs have different shape, which is different from slab ones. Single floors can withstand heavy loads, which is a plus; disadvantages include their high cost and labor intensity.

There are also prefabricated monolithic structures, including prefabricated aerated concrete floors, the top of which is strengthened.

Install a couple of centimeters below the ceilings to avoid pressure and cracks. Aerated concrete floor slabs can act as door and window lintels. When the wall thickness is more than 5 cm, prefabricated lintels are used, the length of which should be 1 centimeter greater than the opening.

















Aerated concrete is the stumbling block of a considerable number of construction-related disputes. Despite the battles, many professional builders believe that it is a good, although not ideal, building material. Just like everyone else. To decide to build a house from aerated concrete blocks, you need to remember that the material has a lot useful qualities, has already become quite widespread.

Selection of wall aerated concrete (gas silicate) blocks Source stroyres.net

A little history

For centuries, people have used natural building stone - tuff - to build houses. It was valued for its lightness, ease of processing and ability to retain heat well. Since the 19th century, scientists have tried to reproduce these qualities by experimenting with concrete mixtures. The consistent work of several researchers is considered important milestones on the path to creating modern aerated concrete:

    Engineer Hoffmann(Czech Republic). In 1889, he conducted a series of experiments with cement mortar, adding acids and salts to it. During the solidification process, the released gases formed a characteristic porous structure.

    Americans Owlsworth and Dyer. In 1914, they were the first to use aluminum and zinc salts. The reaction proceeded with the release of hydrogen, which formed a homogeneous porous structure. The method laid the foundation for future technology.

    Architect Erickson. In 1922, the Swede patented a method for producing cellular concrete using aluminum powder, becoming the godfather of modern autoclaved aerated concrete. The first aerated concrete for the construction of industrial and residential buildings began to be produced in 1929.

Modern house project made from gas silicate blocks Source buildhouse.info

In the USSR, industrial production of cellular concrete was also established in the 30s. The first autoclaved block aerated concrete was produced in Riga in 1937; buildings made from these blocks still stand in the city. In the post-war 50s, aerated concrete helped restore destroyed infrastructure, both in the USSR and in Europe. In modern Russia, the needs for the material are met by more than 80 modern manufacturing plants.

Composition and technology

Aerated concrete is a representative of the category of cellular concrete, building materials, different in properties and operating features. The unifying characteristics are the porous structure, low weight and low density. The following components are used in the production of aerated concrete:

    Astringent. Portland cement.

    Filler. Quartz sand.

    Gas generator. Aluminum powder or paste.

    Industrial purified water.

    Enhancement Additives. Lime, gypsum, industrial waste (slag, ash).

Autoclave curing blocks Source ar.decorexpro.com

The production of aerated concrete begins with mixing the ingredients and pouring the mixture into molds. The chemical reaction produces hydrogen. The gas increases the volume of the mixture (swells it) and forms pores. After the reaction is completed, the mixture sets, it is removed from the molds and cut according to the standard. Further processing occurs in two ways. Depending on which drying method is used, one of two types of aerated concrete is obtained:

    Autoclaved(synthetic) hardening. The blocks gain hardness (steamed) in autoclaves (devices that create high pressure in a water vapor saturated environment).

    Non-autoclaved(hydration, air) hardening. The blocks harden at atmospheric pressure in drying chambers.

Classification

According to the standard, cellular concrete (including aerated concrete) is divided into three types according to its functional purpose:

    Structural. Density ranges from 1000–1200 kg/m³.

    Structural and thermal insulation. From 500 to 900 kg/m³. Brand D500 indicates that in 1 m³ part of the volume is filled with 500 kg hard material, the remaining volume is air filling the voids (cells).

    Thermal insulation. From 200 to 500 kg/m³.

Using blocks increases construction speed Source geo-comfort.ru

Specifications

Aerated concrete serves as an example of the optimal relationship between the main performance characteristics:

    Durability. Despite the low density ( specific gravity), the strength is sufficient for the use of aerated concrete in the construction of load-bearing walls.

    Lightness. The lightness of aerated concrete is due to porosity, which can reach 85-90% of the volume of the material.

    Low thermal conductivity. Good thermal efficiency is also a result of the porosity of the material. Aerated concrete boasts the lowest thermal conductivity coefficient, 0.12 W/m°C (dry).

Homemade mistakes

Having discovered on the Internet many tips for producing aerated concrete with your own hands, and making sure that they are quite feasible, many decide to start their own production. At the same time, home craftsmen do not consider it necessary to strictly comply with technological standards, but they always find people willing to purchase the product at dumping prices.

Small production - no guarantee Source beton-house.com

On our website you can get acquainted with the most popular projects of houses made of aerated concrete blocks from construction companies presented at the exhibition of houses “Low-Rise Country”.

The use of high-quality raw materials and technological equipment in factory production allows us to obtain aerated concrete products with stable physical and chemical characteristics:

    Exact dimensions and correct, with minimal defects, shape.

    Given physical and mechanical parameters.

    Uniform material density, which is confirmed visually (uniform distribution of air cavities).

    Chemical inertness of the material, which is confirmed by laboratory control throughout the production cycle.

The conditions of handicraft production cannot provide manufacturability and control at the level of a modern workshop. Hand-made aerated concrete blocks are distinguishable to the naked eye: the cells (cavities) are distributed unevenly, and the geometry leaves much to be desired. Sometimes such products smell noticeably of chemicals (often lime). Using home-made blocks will most likely reduce the cost of construction, but is guaranteed to become a source of serious problems:

    Blocks with arbitrary density and composition have increased fragility and are highly likely to begin to crack in the first year of operation of the house.

Rough seams will cause heat loss Source bg.decorexpro.com

    Blocks with non-ideal geometry it will not be possible to place it on special glue; you will have to use mortar. Seams with a thickness of 1 to 2 cm will become cold bridges, reducing the thermal efficiency of housing and promoting freezing of the walls.

    Blocks with residual undecomposed lime will have a persistent chemical odor (and affect the health of people living in the house). Excess lime can start the process of corrosion of the metal in the wall.

Advantages and disadvantages of the material

Country gas silicate house has the same strengths and weaknesses, as the source material. Based on the structure of aerated concrete, many advantages can be highlighted:

    Cheapness. Due to the low consumption of cement in the production of products.

    Construction speed. The blocks are significant in size and weigh 3-5 times less than a brick of the same volume. This allows you to build 1 m² of wall in 20-25 minutes, which is unattainable in the case of brickwork.

    Construction costs. Savings come from rational use labor time and construction materials.

Aerated concrete can be processed manually Source kamtehnopark.ru

construction service of houses from aerated concrete blocks

    Low thermal conductivity. According to this indicator, aerated concrete is 2-3 times better than brick. A wall made of 37.5 cm thick blocks retains heat as well as 60 cm thick brickwork.

    Ease of processing. Blocks can be cut by anyone without any problems hand tools, sawed, milled and fined. This flexibility allows you to create complex architectural projects.

    Fire resistance. Aerated concrete is characterized by a high degree of fire resistance and belongs to the flammability group NG (non-combustible). When exposed to a flame with a temperature above 100°C for two hours, an aerated concrete wall begins to lose strength and crack to a depth of 3-4 cm (enough time to leave the house and call the fire brigade). Wooden house During this time it will burn to the ground.

    Vapor permeability. High. Due to the presence of interconnected voids, the material successfully regulates the humidity in the room (breathes).

    Environmental friendliness. The lime and aluminum powder used in production are converted into inert solids after a gas formation reaction. Therefore, the material, made according to all the technology requirements, does not emit any volatile substances into the air.

    This is interesting! On various construction forums you can often find references to a certain table of coefficients of environmental friendliness of materials. There are even some numbers given - for example, for expanded clay this coefficient is 20, for brick - 10, aerated concrete - 2, and the leader and standard is wood - its value is 1. In practice, the existence of such a table is not confirmed in any official document , although if we consider materials specifically in terms of the release of any substances into the air, then there is some truth in such a division.

    Durability. In the Scandinavian countries, Germany and France, there are many houses made of aerated concrete, built 40-50 years ago and still showing no signs of destruction. This durability is due to the quality of the factory-made material and installation carried out in compliance with the technology.

Post-war aerated concrete house Source bwncy.com

    Frost resistance. Aerated concrete resists cyclic freezing well.

Features of aerated concrete blocks determine the weak points of the structure:

    Flexural strength. Aerated concrete is characterized by a relatively low coefficient of ultimate deformation (0.5–2 mm/m). Foundation deformation beyond these limits leads to the appearance of cracks in the wall of the house. The means of combating will be the construction of a solid foundation with monolithic lining or mesh reinforcement, tying the floors and reinforcing the masonry. It is also not recommended to build private houses higher than 3 floors.

    Fasteners. Nails, anchors and screws fit perfectly into an aerated concrete wall, but they stay there disgustingly. A characteristic disadvantage of all cellular concrete is corrected by the use of special fasteners for porous surfaces (steel, nylon, frame). You should also pay attention to the installation of windows and doors (if installed incorrectly, they may become loose over time).

    Adhesion(clutch with finishing materials). It is not high, so before plastering the wall must be prepared (reinforcement or a layer of primer).

External finishing of the facade with plaster Source hug-fu.com

On our website you can find contacts of construction companies that offer house design services. You can communicate directly with representatives by visiting the “Low-Rise Country” exhibition of houses.

    Shrinkage. The shrinkage of non-autoclaved aerated concrete reaches 2 mm/m, autoclaved - up to 1 mm/m.

In order for the constructed house to serve for a long time and without problems, it is necessary to take into account the characteristics of the material:

    Hygroscopicity. A porous wall is capable of absorbing and releasing moisture (like, for example, a wooden wall). To protect the facade from excess moisture, the walls are lined, preferably with ventilation.

    Heating. A house made of aerated concrete can significantly reduce heating costs, but it must be borne in mind that the higher the grade of aerated concrete, the worse it is thermal insulation properties. Energy efficiency can be improved by simple plastering.

    Ventilation. Since aerated concrete is quite large in size building blocks, then the likelihood of poor-quality installation increases, even taking into account the excellent geometry of the products. For example, if the glue is too thick, it does not completely fill the space between the blocks and through gaps form. If there is such a possibility, then after construction it is recommended to conduct a thermal imaging inspection of the house to know whether there are joints and seams that need to be sealed.

Aerated concrete cottage with cladding underneath a natural stone Source pinterest.ch

Myths about technology

Many have encountered not the most flattering reviews about aerated concrete and the performance characteristics of houses that had the misfortune of being built from it. Such judgments and conclusions often have little to do with reality and are caused by a misunderstanding of the characteristics of the material and technology. Most often you can hear such “expert” opinions:

    Aerated concrete walls are prone to cracking. Cracks can appear not only in an aerated concrete wall, but also, for example, in brickwork. After the examination, we have to admit that in most cases the cause of the defect is not the quality of aerated concrete. Most often, the culprit is a poor-quality foundation, the design of which did not take into account the soil characteristics and location groundwater. Another reason may be reinforcement errors (both walls and foundation). The quality of aerated concrete will play an unfortunate role only if garage-made material was used.

    Aerated concrete buildings require insulation. If, when developing a house project, the thickness of wall structures was laid taking into account the norms of SNiP 23-02-2003 (on thermal protection of buildings), additional insulation not required. But since aerated concrete houses definitely need façade finishing, insulation is often installed “at the same time.”

Finishing requires the installation of a ventilated facade Source bankfs.ru

    Aerated blocks for the home are a very fragile material, which splits when hit by a hammer. The same brick can also be split by applying a certain force. According to SNiP, for low-rise construction (up to three floors), aerated concrete blocks of the D500 brand are recommended, which are quite durable and at the same time light and warm. The D400 brand material is more fragile and warm, the D600 brand material is, on the contrary, stronger and colder. Houses built taking into account technological features cope well with the resulting loads, even in seismically active areas.

    Aerated concrete absorbs moisture like a sponge, therefore, a newly built facade requires prompt waterproofing. One of the main features of the material is its gas and vapor permeability, which, however, is not very different from the characteristics of wood. Like wood, aerated concrete is able to absorb moisture and then return it, regulating the microclimate in the rooms. Both materials have a humidity corresponding to the humidity of the surrounding air, and since concrete does not dissolve in water, aerated blocks are not in danger. External walls will not be overly moistened in cottages with year-round living and properly equipped cladding (that does not impede the circulation of moisture).

Video description

About construction from gas silicate blocks in the following video:

    The aerated concrete block gets wet and submerged in water, therefore not suitable for the construction of suburban housing. Strange logic, if you remember that the foam remains on the surface of the water, and the brick instantly sinks to the bottom. The degree of water absorption of an aerated concrete wall during operation is in no way related to buoyancy; these are two different characteristics.

    Living in a house with aerated concrete walls is dangerous, since the material contains lime and aluminum, and the rooms sometimes smell of lime. These elements are part of the original mixture; then they enter into chemical reaction(reaction of transformation, transformation) with other components. The output is fake diamond, aerated concrete in which there are no original elements. For industrial production characterized by precise dosage of starting substances and high-quality drying, as a result of which only safe silicates remain in the material. The smell of lime appears in garage aerated concrete when the components are measured “by eye” and more lime is added than necessary.

Design features of a typical aerated concrete project Source stroyres.net

When developing a project country house made of aerated concrete parts are based on the characteristics of the material. To make housing comfortable and durable, the following points are taken into account:

    Wall thickness. Determined by constructive necessity. Optimal thickness load-bearing walls in climatic conditions middle zone Russia fluctuates between 300-400 mm, interior partitions - 100-150 mm.

    Suitable foundation . For aerated concrete walls, a reliable and stable foundation is important. A monolithic slab base is usually recommended; It is advantageous to use it on various soils.

Video description

About a typical house made of aerated blocks in the following video:

    Roof. Pitched or flat, the roof needs proper installation on aerated concrete walls. Preferred lightweight design with metal tiles, corrugated sheets or bitumen shingles as a roof.

    The need for conservation. Laying of autoclaved aerated concrete is not carried out at temperatures below -5°C. If cold weather sets in, the house is preserved; It is desirable that by this moment it already has ceilings above the first floor. The walls are covered with a waterproofing film, just like pallets with blocks (it is better if they are packed in factory-made shrink tape).

Arrangement of the roof of an aerated concrete house Source bankfs.ru

Subtleties of design

Aerated concrete is a material that offers the most ample opportunities for architectural solutions, one only has to remember the famous Dancing House in Prague. The following requirements apply to the design of a country cottage made of aerated concrete:

    Originality. Details architectural style are able to convey the taste of the owners and emphasize their individuality. Exclusive appearance often achieved by combining modern and traditional styles.

    Practicality(functionality). Currently, houses are being designed from aerated concrete with a thoughtful layout and with any additions - a garage, a terrace (including on the top floor), an attic, a glazed bay window or a balcony.

    Comfort. The concept of comfort can be different, and the interior of a house made of aerated concrete blocks can be decorated in any style, from traditional classic to ascetic minimalist. Often the customer's choice is cozy style country, picturesque Provence or energetic loft.

A modern project with oriental notes Source pinterest.com

Projects and prices of turnkey aerated concrete houses

If you decide to build a house from aerated concrete, its price will in any case be more affordable than a similar brick cottage. Many variables will affect the cost:

    Project type. You can buy popular standard project(with ready-made documentation) or order an individual development that takes into account personal preferences.

    Brands of building materials. The price depends on the manufacturer (domestic or foreign) and the volume of purchase.

    Complexity architectural solution . Determined by the area and number of floors of the project, as well as the type of foundation and roof.

    Relief of the site. If there is a slope on the site, the project will have to be modified.

Video description

About thermal imaging inspection of a house made of aerated blocks in the following video:

By choosing to build a house from aerated concrete blocks on a turnkey basis, you will be able to appreciate all the advantages of this service, because from the moment the contract is signed, all current issues related to the construction of the house become the concern of the contractor:

    Inevitable improvements and changes to the project.

    Geological and geodetic studies of the site.

    Selection of workers and quality control of construction.

    Construction works stipulated in the contract (from the zero cycle with laying the foundation to laying utilities and finishing).

Video description

Today we will discuss how to build an inexpensive house from aerated concrete. How much does a turnkey aerated concrete house cost in the following video:

Of course, you will be able to receive a report at any time or personally monitor how construction is progressing and how the agreed budget is spent.

Country house made of aerated concrete blocks, individual project Source bankfs.ru

When choosing a construction company, you should focus on the time of its existence, the number and quality of completed projects, and reviews from real clients. Companies with extensive experience have their own design bureau, permanent suppliers and professional work teams of various profiles. Construction companies that care about their reputation act according to a well-established scheme, prefer to maintain optimal prices and often have a system of discounts on materials.

Prices for the construction of country houses from aerated blocks in the Moscow region are as follows:

    Area up to 100 m²: on average 2.25 - 3.700 million rubles.

    From 100 to 200 m²: 4,150 - 5,200 million rubles.

    From 200 to 300 m²: 5,560 - 8,670 million rubles.

Conclusion

When planning to build a country house from aerated concrete blocks, you need to be sure that the housing will delight you with comfort for many decades. Such confidence will be given by high-quality raw materials and a reliable construction company, whose specialists know and strictly follow construction technologies.

Homes have been known on the market for quite some time now from lightweight concrete: aerated concrete and foam concrete.

If you have firmly decided to build from aerated blocks, just build, have a good construction. But if you are in doubt, evaluate our offer..

Reasons for the objectivity of doubts about a house made of aerated concrete:

  • high foundation requirements, the need for soil research (geology and geodesy);
  • cracks on the walls as a result any mistakes (it’s better to say this: any mistakes ultimately lead to cracks on the walls) - a sharp decrease in safety and the inability to sell a cracked house - the mistake of building a house from aerated concrete without a professional Technical supervision from the Customer's side(that is, it is paid for by the Customer and is subordinate to the Customer!);
  • low Fire safety houses made of aerated concrete - after exposure to even a small fire, aerated concrete is already destroyed at 600 degrees and the walls must be dismantled.
  • in reality, a turnkey house is built from aerated concrete no less 1.5 years from the start of construction;
  • high costs for interior decoration - plastering and puttying of walls;
  • be sure to buy high-quality aerated concrete with high geometry ( watch below a video from Germany about how hard and through testing the quality of aerated blocks is achieved);
  • mandatory fulfillment of all requirements of aerated concrete manufacturers(the requirements are listed at the bottom of this page) - this is why control by Technical Supervision on the part of the Customer is needed;
  • strict requirements for delivery and warehousing blocks, the need to use trucks with air suspension (didn’t you know?), the need to operate lifting equipment on a construction site;
  • high heating costs houses made of aerated concrete in the absence of main gas ( at the bottom of the page is a video "How they build in Finland", pay attention to the last phrases in the video - last years In Finland they do not build houses using any stone (heavy) technologies. At the same time, Finland has the most stringent requirements for heating engineering and the climatic conditions closest to Russia).

The importance of choosing the right aerated concrete in a short video from the German Yutong plant:

What to do if:

  • there is no time to build an individual house for a long time, or there is no opportunity to control the construction yourself or through independent technical supervision;
  • the budget for a proper aerated concrete house is too large;
  • there is no main gas for heating, or they charge an indecent amount for gas - heating aerated concrete houses with electricity is expensive;
  • it is not possible to drive heavy equipment to the construction site;
  • soils are water-saturated or have weak bearing capacity;
  • The construction area has seismic activity.
  • Construction fully finished house on reinforced concrete slab Full construction in 3-4 months.
  • The difference in cost with a house made of aerated concrete (if it is built according to standards) with an area of ​​180-200 m2 - SAVINGS more than one million rubles.
  • Our modern, capital and solid The house can be heated with electricity without high costs.
  • We make a smart ventilation system and smart system control over home parameters.
  • Author's design project of the facade. And we can bring it to life.
  • Maybe construction of basements and ground floors.

In addition to the price, a significant advantage of houses made of stone panels is their complete Aadaptation to cold climate conditions and lack of main gas for heating .

It will be much easier to warm up a house made of Neo stone SML panels with electricity than a house made of aerated concrete due to the high thermal inertia of the aerated concrete box. Tested by experience.

The photo shows our houses made of Neo stone SML panels.

Let's return to aerated concrete. Why is technical supervision needed when building a house made of aerated concrete? The reason is strict implementation mandatory requirements to the construction of houses from aerated concrete (using the example of the company Ytong).

MANDATORY requirements for transportation, unloading and storage of aerated concrete:

  • transportation of blocks only on vehicles with air suspension (dramatically reduces transport disruption);
  • tightening each row during transportation with a transport tie (to prevent the edges of the blocks from falling off);
  • correct unloading using S-shaped hangers or traverses (other unloading is prohibited to prevent blocks from breaking when the pallet is displaced during its lifting);
  • storing aerated concrete blocks only on a prepared, level area (since it does not bend and breaks);

Compliance with the requirements for transportation, unloading and storage allows you to demand compensation for excess production and transport waste in pallets from the manufacturer (if the breakdown of aerated concrete blocks as a result of delivery was more than 5%).

MANDATORY requirements for construction and installation work:

  • thickness load-bearing wall not less than 250 mm for two floors and 375 mm for three floors;
  • thickness interior partition not less than 150 mm (to meet sound insulation standards);
  • construction only on specialized adhesives(the use of masonry mortar is unacceptable due to a sharp decrease in the thermal performance of the wall and due to a decrease in the mechanical properties of the wall by 4-7 times);
  • applying glue not only to horizontal seams, but also to vertical ones (this requirement is absent in Europe, but in Russia this makes it possible to reduce the ventilation of aerated concrete walls, since the accuracy of cutting blocks of 1-2 mm does not completely eliminate the appearance of through cracks); Use only winter adhesives in winter, and only summer adhesives in summer;
  • mandatory creation of a closed reinforced concrete reinforced belt after each floor to connect all the walls into a single structure;
  • mandatory reinforcement of walls under all window openings ;
  • mandatory use of concrete lintels (not metal corners) over any openings in the walls;
  • maintaining the maximum permitted speed construction and curing of concrete until it reaches strength ( correct term construction of the box for at least 5 months);
  • using only approved types of foundations that completely exclude movement and settlement (factory recommendation: do not plaster the facade for at least 1 year to assess the formation of cracks on the walls);
  • lining a house with bricks only through a ventilated air gap 50 mm;
  • do not use when insulating the facade of a house using extruded polystyrene foam due to its low vapor permeability;
  • proper drying at home inside for finishing (manufacturer's recommendation 6-9 months), since the block has a humidity of 30% and it must first decrease (wet aerated concrete has a low load-bearing capacity and must be loaded carefully), then the humidity must be equalized throughout the entire mass of the block (otherwise there will be shrinkage cracks) and then you need to bring the humidity to 16% and only then start finishing (otherwise cracking is possible decorative finishing);
  • selection of façade finishes according to vapor permeability coefficient: not less than 0.24 for aerated concrete density 400 kg/m3 and 0.21 for density 500 kg/m3.

Fulfilling all these requirements for construction and installation work allows you to build a gas-block house that will not be susceptible to cracking.


Mandatory requirements lead to an objective situation:

  • You will move into a house made of aerated concrete no earlier than in 1.5 - 2.0 years;
  • independent technical supervision paid by the Customer or daily control at the construction site is required;
  • In order for a house made of aerated blocks to be warm, thickness requirements must be met aerated concrete walls, eliminate vertical and horizontal gaps between the blocks, eliminate cracking of the blocks themselves, make the correct facade finishing. Against the backdrop of increasingly stringent requirements for heating engineering in Russia (according to the order of the Ministry of Construction, in 2018 the standards were increased by 20%, the next increase is 40% in 2023, and 50% in 2028. Moreover, even the requirements for heating engineering in 2017 (before the tightening of standards ) demanded a thickness of aerated concrete walls of 400 mm for the Moscow region. What will happen by 2028? The thickness of the aerated concrete wall will have to become a meter thick. It is because of this that in Finland they stopped building houses using any heavy technologies - see the video at the end of the page.
  • EVENTUALLY the right house Aerated concrete always ends up being expensive. It simply cannot be cheap based on the results of meeting all the standards.

Video about houses in Finland. Pay attention to the words at the end that in Finland, in recent years, heavy houses have not been built.

Worthy and profitable.
More than 570 constructed facilities in Russia

I'm new to both the forum and construction, so please don't judge too harshly. We will talk about a certain type of ceiling, which is somehow not very well lit and, apparently, not very popular. These are reinforced aerated concrete floor panels. Meanwhile, this type of flooring has undeniable advantages over traditional ones, namely:
1. Thermal insulating properties - aerated concrete cannot be compared with reinforced concrete.
2. Lightness. A standard panel 600x250 mm long 4.9 m weighs only 850 kg. This is important both for unloading (the manipulator can handle it easily) and for installation (for any crane this is not a load at all).
3. Speed ​​and ease of installation - in my practice, it is possible to completely cover a 10x11 m floor in 4 hours.
4. Strength is quite sufficient, 600 kg per m2.
5. Ease of punching holes for the passage of communications - a hole with a diameter of 150 mm will require no more than 10 minutes, taking into account the removal of reinforcement.
6. Absolutely do not require any additional work for styling (I believe that it is still advisable to place them on the arm belt). After installation, reinforcement of joints and filling will not take more than 1 day. minimum quantity solution.
7. The accuracy of the dimensions in width is such that if you put 15 panels close to each other, you will be surprised that the width will be exactly 15 times the width of 1 panel with an accuracy of a few cm.
8. It is easy to cover any width, since you can order not only standard widths, but also reduced ones - 500 mm and 400 mm. Which is very convenient.
9. The length of the panels also allows for a lot - I used 3 lengths - 2.4 m, 3.5 m and 4.9 m, but there are more.
10. Any screw twisting of these panels is completely eliminated by their production technology, so you get a 100% flat floor and ceiling (the difference can only be due to the poor quality of the surface on which the panels are placed).

Now a little about the shortcomings. This, of course, is not a very small price - 1 floor of a 10x11 m house will cost somewhere around 110 thousand + delivery + unloading + crane for installation. But what to do? And of course, it is impossible to lay communications in such an overlap. But this is a completely fixable problem. And it’s not even a problem at all.

So, if anyone is interested, please look at the photos from my construction:
1. This is how the panels arrive on the truck. They are knitted in 2 or 3 pieces. The manipulator can take 3 short panels or 2 medium ones or only 1 long one at once. Unloading and storing takes 4.5 hours and approximately 10 thousand money:

2. And these panels are mounted. A special welded “goat” is used, which allows the panel to be brought close to the previous one. You can install it without a goat (with the help of a jack and some kind of mother), but then the installation time will increase by at least 1.3-1.4 times. The faucet will take at least 16 thousand in 5+1 hours, so exceeding the limit will hurt your pocket:

3. This is how the panels lie on the plinth, the floor of the 1st floor is however the simplest:

4. This is already the installation of the 1st floor ceiling. This is how the panel is taken with tapes (preferably wide, so as not to damage - aerated concrete is fragile), then laid on 2 pallets so that it can be grabbed by a goat for installation:

5. Installation of the 2nd floor ceiling - the lower part of the goat is clearly visible. Crane operator installs most panels of this ceiling are blind, which requires good coordination between the guys during installation:

6. Here you can clearly see what the ceiling looks like:

7. And this is the ceiling of the 2nd floor after filling and waterproofing the seams:

8. Just in case, I also give the result of 2 years of work - these are 2 floors of a 10x11 m house made entirely of 100% aerated concrete on monolithic slab.

9. As a fan of aerated concrete, please pay attention to the arched lintels in the previous photo (I ordered them together with the floors). The stairs to the 2nd and 3rd floors also have steps made of reinforced aerated concrete.

For reference, for those interested - the foundation cost about 350 thousand, the basement with the 1st floor (including ceiling) is almost 500, the 2nd floor with the laying of pipes, cables and chimney - about 400. Three guys from the near eastern countries worked, I did the project myself using the Google program SketchUp, and the main advantage of this program is that even Eastern children can master it if you give them a computer and teach them how to press buttons. This allowed me to come to the site mainly only on weekends.

The roof remains, but that will happen next year (too expensive all at once). For the winter, the top will be covered with an 11x12 banner - I’ve already checked it, it hardly leaks.

And one last thing. If anyone wants to do the same, I have a ready-made “goat”, I’ll give it to you at a low price. good hands.